Search results for " Electrochemical sensor"
showing 10 items of 15 documents
Copper nanowires as higly sensitivite electrode for nitrate ions in water
Agricultural and livestock sectors are the main sources of nitrate ions contamination in water and foodstuff. [1]. High nitrate concentration is dangerous for both environment (algae overgrowth) and human health. Nitrate ions can be converted in different harmful nitrogen based compound such as NO2-, NO, N-nitroso compounds [2] that are responsible of several diseases such as cancer, Parkinson [3-4]. For these reasons, the Environmental Protection Agency, has established the maximum amount of nitrate ions in drinkable water at 44 mg/l, limit that is valid in many European countries [5]. Generally, spectroscopy techniques are the most used because allow to carry out analyses with high precis…
Reduced graphene oxide decorated with metals nanoparticles electrode as electrochemical sensor for dopamine
2019
Dopamine (DA) is one of the most important neurotransmitters that influences the processes that involve memory, sleep, mood, learning among others [1]. In fact, in the last years, dopamine concentration in human body fluids has been related to some neurodegenerative diseases, such as Parkinson and Alzheimer's diseases [2]. The possibility to have a bio-marker for these disease is of extreme importance because, disease related with dementia, are diagnosed when they are already developed and their management become almost impossible. The possibility to continuously monitor DA level in fluids, such as blood and urine, could accelerate the early diagnosis of these diseases. The principal analyt…
FLEXIBLE ELECTRODE BASED ON GOLD NANOPARTICLES AND REDUCED GRAPHENE OXIDE FOR URIC ACID DETECTION USING LINEAR SWEEP VOLTAMMETRY
2021
In this work, an electrochemical sensor for uric acid determination is shown with a preliminary study for its validation in real samples (milk and urine). Uric acid can be electrochemically oxidized in aqueous solutions and thus it is possible to obtain electrochemical sensors for this chemical by means of this electrooxidation reaction. Indium tin oxide coated on flexible polyethylene terephthalate substrate, modified with reduced graphene oxide and gold nanoparticles by co-electrodeposition, was used. Electrodeposition was performed at -0.8V vs SCE for 200 s. All samples were characterized by electron scan microscopy and electron diffraction spectroscopy. A careful investigation on the ef…
FABBRICAZIONE DI SENSORI ELETTROCHIMICI NANOSTRUTTURATI PER APPLICAZIONI NELL’INDUSTRIA ALIMENTARE E BIOMEDICHE
2023
Phosphate ions detection by using an electrochemical sensor based on laser-scribed graphene oxide on paper
2023
In this work, electrodes based on laser-scribed reduced graphene oxide were fabricated using filter paper as the substrate. To fabricate the electrodes, a water suspension of graphene oxide was filtered to produce a continuous and uniform film of graphene oxide on the filter paper surface. Subsequently, a CO2 laser was used to "write" the working, counter and reference eelctroes by reducing graphene oxide in specific areas to define complete sensors. Referecnce electrodes were then coated with a commercial Ag/AgCl conductive paste to produce a quasi Ag/AgCl reference. As fabricated devices were employed as electrochemical sensors for detection of phosphate ions in water by employing the mol…
Electrochemical Quantification of H2O2 Released by Airway Cells Growing in Different Culture Media
2022
Quantification of oxidative stress is a challenging task that can help in monitoring chronic inflammatory respiratory airway diseases. Different studies can be found in the literature regarding the development of electrochemical sensors for H2O2 in cell culture medium to quantify oxidative stress. However, there are very limited data regarding the impact of the cell culture medium on the electrochemical quantification of H2O2. In this work, we studied the effect of different media (RPMI, MEM, DMEM, Ham’s F12 and BEGM/DMEM) on the electrochemical quantification of H2O2. The used electrode is based on reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) and was obtained by co-electrode…
A Comparative Study of Poly(Azure A) Film-Modified Disposable Electrodes for Electrocatalytic Oxidation of H₂O₂: Effect of Doping Anion.
2018
In the present paper, poly(azure A) (PAA) films were electrosynthetized in the presence of different doping anions on disposable screen-printed carbon electrodes (SPCEs). The anions used included inorganic monoatomic (chloride and fluoride), inorganic polyatomic (nitrate and sulfate) and organic polyatomic (dodecyl sulfate, DS) species. The coated electrodes thus obtained were characterized by electrochemical techniques and SEM. They showed improved electrocatalytic activities towards hydrogen peroxide oxidation compared to that of a bare SPCE. In particular, the insertion of DS anions inside PAA films provided a special sensitivity to the electrocatalysis of H2O2, which endowed these elect…
Silver based sensors from CD for chloride ions detection
2021
This preliminary work shows a new and innovative way to produce silver based electrodes from compact discs and its application towards the detection of chloride ions. A complete sensor was obtained from the compact discs with working, reference and counter electrode made of silver. Chloride ions were detected by exploiting the high affinity of silver with this anion to produce silver chloride. This electrochemical oxidation of silver can be monitored by using an electrochemical technique such as linear scan voltammetry. Indeed, during linear scan voltammetry the oxidation of silver to silver chloride lead to a peak current that increases linearly with chloride concentration. Using this tech…
DOPAMINE ELECTROCHEMICAL SENSOR BASED ON REDUCED GRAPHENE OXIDE AND METAL NANOPARTICLES
2019
Dopamine (DA) is one of the most important neurotransmitters released from the brain, and is involved in many different biological processes. This neurotransmitter influences the processes that involve memory, sleep, mood, learning, and so on. Besides, in the last years, dopamine concentration in human body fluids has been related to some neurodegenerative pathologies, such as Parkinson and Alzheimer’s diseases [1]. It is well known that these pathologies are due to the formation of amyloids plaques that block part of the brain. Many literature data reports that DAergic neurons (areas of midbrain where DA is synthesized) shows a different activity when amyloid plaques are present with a con…
Green and Integrated Wearable Electrochemical Sensor for Chloride Detection in Sweat
2022
Wearable sensors for sweat biomarkers can provide facile analyte capability and monitoring for several diseases. In this work, a green wearable sensor for sweat absorption and chloride sensing is presented. In order to produce a sustainable device, polylactic acid (PLA) was used for both the substrate and the sweat absorption pad fabrication. The sensor material for chloride detection consisted of silver-based reference, working, and counter electrodes obtained from upcycled compact discs. The PLA substrates were prepared by thermal bonding of PLA sheets obtained via a flat die extruder, prototyped in single functional layers via CO2 laser cutting, and bonded via hot-press. The effect of co…